The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the fridge section and the fridge section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located.----------- But in yoiur case the freezer section gets cool, it freezes, but will not defrost the ice.Its not starting defrost cycle, so just freezer gets cooling, but fridge section does not get cold.-----------------
First try manual defrost reset procedure. The procedure is as follows: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. Then its defrost board problem. -------------